『On site display of vortex flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. What should I do if the vortex flowmeter keeps showing zero?
What should I do if the vortex flowmeter keeps showing zero? There are several reasons why the vortex flowmeter keeps displaying zero: the caliber is chosen to be too large. The maximum range of the sail key on site cannot reach the minimum range of the vortex flowmeter, so it keeps displaying as zero. Use a wooden stick or other object to tap the pipeline part of the flowmeter to see if there is any flow display. If there is, it can be basically confirmed that the caliber selection is too large. The minimum flow rate of the sparrow sedan cherry set by the vortex flowmeter at the factory needs to be changed. Try to adjust to the lower limit of the minimum flow rate of the flowmeter (provided that there is no vibration source on site), otherwise, vibration will affect the accurate measurement of flow rate. During the transportation of the flowmeter, the wire ends between the sensor and the circuit board became loose and fell off, and the main board could not receive signals from the sensor. The probe head of the cluster sensor of the vortex flowmeter is burned out due to high temperature or other reasons, and the probe head of the sensor is damaged. The above reasons are more likely. It is recommended to contact the manufacturer according to the situation and return to the factory for inspection.
2. Why does the vortex flowmeter display normal cumulative flow and abnormal instantaneous flow?
A vortex flowmeter is installed on site for measuring water flow, using a split installation method. The on-site equipment is running normally, but it was found that the instantaneous flow rate is displayed as zero, while the cumulative flow rat
_600x400.jpg)
3. Why does the vortex flowmeter display normal cumulative flow and abnormal instantaneous flow?
A vortex flowmeter is used to measure the flow rate of water, which is installed separately. A vortex flowmeter sensor is installed on site to output pulse signals and used in conjunction with a flow integr